Keyboard shortcuts

Press or to navigate between chapters

Press S or / to search in the book

Press ? to show this help

Press Esc to hide this help

Project Cycle Count KPI

Description

The Project Cycle Count KPI estimates the number of full charge-discharge cycles a battery storage system performs in a single day. This KPI is essential for understanding battery utilization and degradation over time.

The KPI is calculated daily and reported as a floating-point number, where 1.0 represents one full cycle (100% discharge followed by 100% recharge, or equivalent cumulative partial cycles).

Methodology

  1. Retrieve time-series data for:

    • project_soc_percent: The State of Charge (%) of the project’s battery system over the day.
  2. Convert timestamp index:

    • The index is standardized to ensure consistent time stepping.
  3. Calculate absolute changes in SOC:

    • Take the absolute difference in SOC between each pair of consecutive time steps.

  4. Sum the absolute changes and normalize by 2:

    • The total cycle count is estimated by summing all absolute SOC changes and dividing by 2. This accounts for the fact that a full cycle consists of both discharge and charge.

  5. Round and store the KPI result:

    • The daily cycle count is rounded to four decimal places and stored as a project-level KPI for the given date.