Combiner Field Health KPI
Description
The Combiner Field Health KPI measures the DC health of a project based on combiner current data. Each combiner receives a daily health score ranging from 0 to 1, where a score of 1 indicates the healthiest combiners on the project.
Methodology
- Retrieve DC combiner current data for each combiner box on a 5-minute interval. The data is filtered to focus on the time window from 11:30 AM to 12:30 PM to capture peak irradiance conditions.
- Normalize each combiner's current against its own DC capacity to account for differences in combiner size.
- Identify the "ideal" combiner by calculating the 99th percentile of all normalized combiner currents. The 99% threshold is chosen to exclude outliers and focus on typical combiner performance.
- Normalize all combiners' ratios against the ideal combiner. This gives the ideal combiner a score of 1.0, with all other combiners having a score ranging from 0 to 1. Outliers may exceed a score of 1.0.
- Calculate the daily mean score of each combiner trace to calculate the overall DC Field Health for each combiner on that day.
- Calculate the mean of all combiner scores to derive the overall DC Field Health for the project on that day.