Specific Yield KPI

Description

The Specific Yield KPI quantifies how much AC energy is delivered per unit of installed DC capacity. It provides a normalized metric for evaluating site performance independent of plant size and is especially useful for comparing across projects.

This KPI is calculated daily and expressed in units of kWh/kWp.

Methodology

  1. Retrieve time-series data for:

    • meter_active_power: AC power delivered by the site over the day.
  2. Clean and aggregate the data:

    • Clip negative values to zero to eliminate erroneous readings.
    • Resample data to hourly averages to standardize granularity.
  3. Calculate total energy delivered:

    • Integrate the hourly AC power measurements to get total daily energy output in kWh.
  4. Normalize by DC capacity:

    • Divide the total energy output by the site’s installed DC capacity (also referred to as kW-peak, or kWp) to get the specific yield.
  5. Compute Specific Yield:

    • The formula is:

  6. Store the KPI result:

    • The resulting value is stored as a project-level KPI for the corresponding date.